Aid 4D probe; recognize the probe by means of the ID code; switch the 4D push signal by using the electrical relay for making the 4D probe perform Ordinarily. four.two.two Main board The principle board may be divided into two components: front-close of the primary board and again-conclusion of the principle board.
one.2.2 Warning Labels Warning Labels Which means Be sure to meticulously read through this guide in advance of use system. The subsequent labels can be a. Usually do not spot the gadget on the sloped area. If not the available when the system machine may possibly slide, resulting in own personal injury or perhaps the device works While using the mobile malfunction.
Analyzing sufferers in now’s demanding atmosphere needs modern know-how that enables clinicians for making fast and self-assured diagnoses. The flexibility on the DP-50 expands your clinical utility while helping to improve patient treatment.
The consumer will not be allowed to open up the handles and panel on the procedure, neither Notice: machine disassemble is allowed. To make sure the technique functionality and basic safety, only Mindray engineers or engineers authorized by Mindray can complete upkeep.
Explore superior diagnostic details through extended see in the anatomical framework on all convex probes.
Slice off cable ties connecting the key unit on the Display screen by diagonal chopping pliers, and after that pull out the corresponding cable plugs.
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
Mindray’s new generation of black & white ultrasound method, DP-fifty Qualified, is provided with Superior imaging technologies enabling deeper penetration and a lot quicker image acquisition with increased resolution.
Observe: Prior to uploading the log, ensure the ultrasound technique has long been connected to network, in any other case, the program may possibly warn “couldn't connect with server” The server (smtp.
After prosperous relationship, the freshly extra community printer identify will likely be proven while in the printer driver checklist. Observe: Prior to hook up the network printer, be certain the ultrasound program as well as the printer are in the exact same community area, plus the community is Doing the job Typically. The IP handle and the server name need to be legitimate, e.g. Web site 47 DICOM Placing Enter the AE Title from the ultrasound process, port and PDU based on the actual condition, and afterwards click [Okay] to exit the display.
Be aware: About the observe, the brightness adjustment will come ahead of contrast. Following readjusting the observe’s contrast and brightness, adjust all preset and peripheral settings.
NOTE: Just before inserting the connector in the probe port, inspect the connector pin. If the pin is bent, usually do not make use of the probe until finally it has been inspected / fixed / changed. Putting in Peripherals To the styles of the supported peripherals, please consult with “2.
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Not all products and services listed are available outside the house the U.S. and a few are issue to country unique restrictions.
Click Agree and Carry on to accept cookies and go on to the internet site or click on More details to check out in depth descriptions of the categories of cookies and choose irrespective of whether to accept specific cookies even though on the site.
five.2.three Geometric positioning precision Longitudinal geometric positioning precision Examination Stage: Do changes as the best way in testing the maximum depth. Document the distance by 20mm Each and every section within the longitudinal targets line using the measurement caliper; Find the value with the greatest mistake (to 20mm), compute the precision using the formulation down below The measurement caliper should be positioned at the higher fringe of the goal, NOTE:... Site seventy nine Transverse geometric positioning accuracy Test Phase: Go over the scan area with the phantom with h2o or pair gel, Carefully Get hold of the probe Together with the scan floor Adjust the depth, building the transverse targets to generally be exhibited from the picture. Modify the main target place to generally be posited beside the transverse targets (the conventional is not apparent) Change parameters like obtain, TGC, creating Every transverse targets to be Obviously exhibited. Web page 80 five.five.two.four Blackout Area Test Action: Protect the scan surface of the phantom with water or couple gel, gently Get in touch with the probe Along with the scan area Regulate the depth in a reduce worth, Dp50rb and set the main target at the closest location to the scan floor. Lessen the value of parameters like AP, Obtain until eventually the qualifications sound just could be observed. Website page 81: Software Enhance And Servicing